FLORET FO 4000 PG Series Equivalent — Cationic PAM Powder Screening for PG0 to PG3 Grades
✦ Alternative Supply Route for SNF FLORET FO 4000 PG series

FLORET FO 4000 PG Series Equivalent — Cationic PAM Powder Screening for PG0 to PG3 Grades

ChinaPAM supplies cationic polyacrylamide powder for FLORET FO 4000 PG requirements. Send the exact FO number with its PG0, PG1, PG2, PG3 or PG suffix, quantity and destination and we will name the ChinaPAM screening grade, quote current pricing and plan a furnish evaluation. In this family the suffix, not the base number, sets the molecular-weight tier and the make-up limits.

Supply Route Comparison

Published reference data and the ChinaPAM route for SNF FLORET FO 4000 PG series

Competitor figures are from the archived SNF powder and bead catalogue, tables FLORET FO 4000 PG0 & PG1 and PG2 & PG3 (PDF pages 16 and 17). The printed edition year of this archived catalogue is not confirmed. SNF states these data are given for information only and do not constitute a specification. They are historical indicative values under SNF test conditions, not ChinaPAM specifications and not evidence of current SNF availability.

ParameterChinaPAM Supply RouteSNF FLORET FO 4000 PG series
Physical formCationic polyacrylamide powderCationic polyacrylamide powder for paper retention
Grades coveredCharge-band lanes with a molecular-weight bracketFourteen PG0 / PG1 / PG2 / PG3 / PG grades
Molecular-weight positionChinaPAM scale; confirmed by furnish evaluationPG0 Very High, PG1 High, PG2 Standard, PG3 Medium, FO 4248 PG Standard
Charge positionMatched by band, then evaluatedVery Low, Low and Medium (SNF scale)
DissolutionMeasured on the quoted gradePG0 120 min; PG1 90 min; PG2, PG3 and FO 4248 PG 60 min
Recommended / maximum make-upPer the TDS of the selected gradePG0 3 / 5 g/L; other tiers 4–5 / 10 g/L
Paper performance and contact useNo retention performance or paper-contact certification claimedListed by SNF for paper retention
PackagingConfirmed in the quotation25 kg bags / 750 kg big bags

Specifications

Product FormCationic polyacrylamide powder
Series CoveredFourteen FLORET FO 4000 PG0 / PG1 / PG2 / PG3 / PG grades
Very Low / Low-Charge LaneC8008 charge-led start
Medium-Charge LaneC8001, C8015
Molecular-Weight BracketC8003, C8035 for the PG0 and PG1 tiers
DocumentsTDS for the selected grade; COA per confirmed shipment
Packaging / Lead TimeConfirmed in the quotation

Key Features

  • Fourteen PG columns read by full suffix, not by base number
  • PG0 make-up limit carried into the preparation plan
  • Charge-led lane plus a molecular-weight bracket for each tier
  • Furnish evaluation documented before any machine trial
  • Quotation, evaluation plan and documents through one enquiry

Applications

  • FO 4000 PG supplier-change qualification
  • Retention-aid shortlist screening on a customer furnish
  • Make-up plan review when a PG0 grade is in use
  • Checking a tender line that names a FLORET PG grade

Get a Quote for SNF FLORET FO 4000 PG series Alternative Supply

Tell us your exact FO number with its PG suffix, quantity and destination. We will name the ChinaPAM screening grade, quote current pricing and set up a furnish evaluation plan.

We will reply with the ChinaPAM grade for your PG line, current pricing, the applicable TDS and an evaluation plan.

FO 4000 PG Grade Selector: Fourteen Columns, Read by Suffix

Find the exact FO number and PG suffix on your label, then start from the lane on that row. ChinaPAM has no low-charge cationic row at very high or standard molecular weight, so each lane pairs a charge-led start with a chain-length bracket and the furnish evaluation decides. The two qualitative scales do not convert numerically.

Archived SNF catalogue indicative figures (PDF pp.16–17) beside the ChinaPAM starting lane
Exact SNF gradeSNF charge / MWBrookfield cps at 5 g/LRec. / max. g/L; dissolutionChinaPAM start + bracket
FO 4190 PG0Low / Very High4503 / 5; 120 minC8008 + C8003, C8035
FO 4240 PG0Low / Very High5003 / 5; 120 minC8008 + C8003, C8035
FO 4140 PG1Very Low / High3005 / 10; 90 minC8008
FO 4190 PG1Low / High5004 / 10; 90 minC8008 + C8003, C8035
FO 4240 PG1Low / High6004 / 10; 90 minC8008 + C8003, C8035
FO 4290 PG1Low / High7004 / 10; 90 minC8008 + C8003, C8035
FO 4190 PG2Low / Standard4005 / 10; 60 minC8008
FO 4240 PG2Low / Standard6005 / 10; 60 minC8008
FO 4290 PG2Low / Standard6005 / 10; 60 minC8008
FO 4350 PG2Medium / Standard6005 / 10; 60 minC8001, C8015
FO 4440 PG2Medium / Standard6505 / 10; 60 minC8001, C8015
FO 4190 PG3Low / Medium3005 / 10; 60 minC8008
FO 4350 PG3Medium / Medium3505 / 10; 60 minC8001, C8015
FO 4248 PGLow / Standard5004 / 10; 60 minC8008

Three FO 4000 PG Facts Buyers Can Trace

Tiers: SNF maps PG0, PG1, PG2 and PG3 to Very High, High, Standard and Medium molecular weight, all cationic powder listed for paper retention. FO 4248 PG sits in the PG2 table at standard molecular weight with a lower bulk density of 0.69.

Dissolution follows the tier: 120 minutes for PG0, 90 minutes for PG1 and 60 minutes for PG2, PG3 and FO 4248 PG.

Make-up limits follow the tier too: PG0 lists 3 g/L recommended and 5 g/L maximum, while most PG1 to PG3 columns list 4 or 5 g/L recommended and 10 g/L maximum. SNF gives viscosities as average indicative values and notes that a viscosity ten times lower can be used when choosing preparation and dosing equipment.

Two Failure Modes to Check Before Bulk Supply

Both come from reading the base number and skipping the tier.

Trigger, symptom and check for FO 4000 PG supplier-change planning
Failure modeTriggerSymptomCheck
Base number quoted aloneFO 4190 or FO 4240 is ordered without PG0, PG1, PG2 or PG3Grade from a different molecular-weight tier and preparation window arrives on siteQuote from the full label, and record the tier on the purchase order and COA request
PG0 prepared on a 10 g/L set-upA make-up unit sized for 10 g/L is used for a PG0 position listed at 5 g/L maximumThe make-up runs outside the condition the incumbent grade was listed forValidate the preparation route on the ChinaPAM grade at your actual concentration before use

Documented Furnish Evaluation Plan

Prepare the incumbent PG grade and the ChinaPAM shortlist at the same concentration, inside the limits of the exact tier, and time dissolution. Record solution viscosity and solution age before dosing.

Evaluate on your own furnish and system chemistry with stepped doses, recording the retention and drainage measures your mill already uses. The result is documented before any machine trial is scheduled; ChinaPAM does not claim retention performance in advance.

What to Send for a Quotation

The exact FO number, PG suffix and quantity are enough to start pricing. These details sharpen the evaluation:

InputWhy it matters
FO number with PG0, PG1, PG2, PG3 or PG suffixSets the tier, dissolution time and make-up limit
Paper grade, furnish and addition pointDefines the evaluation conditions
Make-up concentration and preparation unitChecks the route against the tier limit, especially PG0
Compliance documents your mill requiresReviewed before the quotation is finalised
Expected volume and destinationPricing, packaging and lead time in the quotation

Documents and Delivery

The applicable TDS is confirmed together with the selected ChinaPAM grade, and a batch COA is tied to the confirmed shipment. Packaging and lead time are confirmed in the quotation for your volume and destination.

Dosage Guide

Start from your current PG dose and addition point. Prepare the ChinaPAM grade at the same working concentration within the tier limit, allow full dissolution, and compare stepped doses on your own furnish. Schedule any machine trial only after the documented evaluation.

Verified manufacturing credentials (ISO 9001 / 14001 / 45001, HSE)

Frequently Asked Questions — FLORET FO 4000 PG Series Equivalent — Cationic PAM Powder Screening for PG0 to PG3 Grades

Can ChinaPAM supply for a FLORET FO 4000 PG requirement?

Yes, as cationic polyacrylamide powder. Send the full FO number with its PG suffix, quantity and destination and we will name the screening grade, quote current pricing and arrange a furnish evaluation plan.

FO 4190 appears as PG0, PG1, PG2 and PG3. Does the suffix matter?

Yes. The same base number sits in four molecular-weight tiers with different dissolution times and make-up limits: 120 minutes and 5 g/L maximum for PG0, 90 minutes for PG1, 60 minutes for PG2 and PG3. Quote and test against the full suffix.

Can I prepare a PG0 replacement at 10 g/L like other grades?

SNF lists PG0 at 3 g/L recommended and 5 g/L maximum. If your current set-up runs at 10 g/L, tell us, and the preparation route is validated on the ChinaPAM grade at your real concentration before it is used.

Will the ChinaPAM grade deliver the same retention on my machine?

ChinaPAM does not claim paper-retention performance or paper-contact certification. The grade is selected by charge band and confirmed by a documented evaluation on your own furnish before any machine trial.

Which documents come with the supply?

The TDS for the selected ChinaPAM grade is confirmed with the grade, and a batch COA is tied to the confirmed shipment. If your mill needs specific compliance documents, list them in the enquiry so they are reviewed before the quotation is finalised.

Trademark notice. SNF FLORET FO 4000 PG series and all other third-party product and brand names on this page are trademarks or registered trademarks of their respective owners. Henan Jinghua New Material Technology Co., Ltd. is not affiliated with, endorsed by, sponsored by or authorised by those owners, and no such relationship is implied. Those names are used here for the sole purpose of identifying the products our grades are compared against, which is necessary to describe what we supply. Our products are separately branded ChinaPAM grades and are not licensed copies. Grade descriptors quoted for third-party products are taken from each manufacturer’s own published literature and follow that manufacturer’s own scale; we do not publish figures those manufacturers do not publish. Performance on your process should be confirmed by jar test or CST test before any change of supply.