FLOPAM AN PWG and SEP Grades — Polyacrylamide Selection Route with Document Check
✦ Alternative Supply Route for SNF FLOPAM AN PWG and SEP grades

FLOPAM AN PWG and SEP Grades — Polyacrylamide Selection Route with Document Check

ChinaPAM answers FLOPAM PWG and SEP enquiries with a polyacrylamide selection route: we identify the base grade and ion type, name a nonionic or anionic screening lane, and confirm which market and project documents your drinking-water duty requires before the quotation is finalised. Send the full grade, the duty and the documents your authority asks for.

Supply Route Comparison

Published reference data and the ChinaPAM route for SNF FLOPAM AN PWG and SEP grades

Competitor figures are from SNF, FLOPAM AN PWG & SEP (drinking water production) table in the FLOPAM Catalogue 2007 (PDF pages 50–51). SNF states these data are given for information only and do not constitute a specification. They are historical indicative figures under SNF test conditions, not ChinaPAM specifications and not evidence of current SNF availability.

ParameterChinaPAM Supply RouteSNF FLOPAM AN PWG and SEP grades
Ion typeNonionic or anionic lane by base gradeFA 920 columns non-ionic; AH 912 very low charge; AN 905 to AN 956 low to high charge
Suffix meaningNot interpreted; base grade decides the lanePWG and SEP not defined in the catalogue
PWG versus SEP valuesMeasured on the quoted ChinaPAM gradeIdentical published values within each pair
Charge, viscosity, make-up, dissolutionPer the TDS of the selected gradeGiven per base grade in the p.50–51 table
Drinking-water statusNot claimed; required documents confirmed per projectTable heading: drinking water production
DocumentsTDS with the selected grade; COA tied to the confirmed shipmentCatalogue data, stated not to be a specification

Specifications

Product FormPolyacrylamide powder (nonionic or anionic by base grade)
Grades Covered16 columns: FA 920, AH 912, AN 905, AN 910, AN 913, AN 923, AN 934, AN 956 — each PWG and SEP
Route TypeSelection route by base grade and ion type
FA 920 LaneNonionic screening (1003)
AH 912 LaneVery-low-charge anionic screening (1082)
AN 905 to AN 956 LaneAnionic screening by base-grade charge position
Compliance DocumentsRequired market and project documents confirmed before the quotation is finalised
Packaging / Lead TimeConfirmed in the quotation

Key Features

  • Selection by base grade and ion type, not by suffix
  • Nonionic and anionic columns kept apart
  • Drinking-water document requirement checked before quotation is finalised
  • No compliance status inferred from a PWG or SEP suffix
  • Quote, jar-test plan and documents through one enquiry

Applications

  • FLOPAM PWG or SEP supplier-change assessment
  • Base-grade and ion-type identification from a tender or label
  • Document requirement check for a drinking-water project
  • Same-water jar-test screening for grade selection

Get a Quote for SNF FLOPAM AN PWG and SEP grades Alternative Supply

Tell us your full PWG or SEP grade, the documents your project requires, the duty, quantity and destination. We will name a screening lane, confirm the document position and quote current pricing.

We will reply with the base-grade identification, the screening lane, the document position, current pricing and a jar-test plan.

Sixteen Exact Columns, Eight Base Grades

SNF pp.50–51 place every base grade twice, once with PWG and once with SEP, and publish the same values for both. The practical reading is simple: identify the base grade and its ion type, then keep the full suffix on your documents for traceability.

Three published facts in that table do most of the selection work. All sixteen columns are listed Very High molecular weight, so the suffix and the base grade are not telling you anything about a molecular-weight step. Make-up and dissolution split the table in two: FA 920 and AH 912 are listed at 5 g/L recommended, 10 g/L maximum, with 180 and 150 minutes to dissolve, while every AN column is listed at 3 g/L recommended, 5 g/L maximum, and 90 minutes. And the approximate Brookfield viscosity at 5 g/L does not simply climb with charge — it runs 100, 350, 450, 800, 1200, 1395, 1715 up to AN 934, then falls back to 1600 for the higher-charge AN 956.

FLOPAM PWG/SEP base grades in the SNF 2007 drinking water production table (identical values published for the PWG and the SEP column of each grade) and the ChinaPAM starting direction
Base grade (PWG + SEP)Charge densityRec. / max make-up (g/L)Dissolution @ 5 g/L, 25°C (min)ChinaPAM starting direction
FA 920Non-ionic5 / 10180Nonionic lane (1003)
AH 912Very low5 / 10150Very-low-charge anionic lane (1082)
AN 905Very low3 / 590Very-low-charge anionic lane
AN 910Low3 / 590Low-charge anionic lane
AN 913Low3 / 590Low-charge anionic lane
AN 923Medium3 / 590Medium-charge anionic lane
AN 934Medium3 / 590Medium-charge anionic lane
AN 956High3 / 590Higher-charge anionic lane

Documents First: What the Suffix Cannot Tell You

The table heading says drinking water production. That describes SNF’s product positioning in 2007, not the status of any ChinaPAM grade. Requirements differ by country and project, so we ask which documents your authority or client specifies and confirm what can be supplied before the quotation is finalised.

A food-grade note on another product line is not a drinking-water document and is not offered as one.

Two Ways a PWG/SEP Changeover Goes Wrong

Treating the suffix as a compliance proof. A PWG or SEP label does not make a replacement grade acceptable for drinking-water use. The required market and project documents must be confirmed first.

Choosing by the shared application heading, or by the neighbouring column. FA 920 PWG and AH 912 PWG sit side by side on p.50 under one heading, but SNF lists FA 920 as non-ionic and AH 912 as very low charge — two different ion types, and two different ChinaPAM lanes. The published make-up and dissolution figures for those two columns (5 g/L, 180 and 150 minutes) also differ from every AN column (3 g/L, 90 minutes), so a preparation routine carried over from the wrong column can leave the polymer under-hydrated. Confirm the full grade and the water-treatment duty before any lane is quoted.

Selection and Jar-Test Plan

Once the base grade and document requirement are clear, the ChinaPAM screening grade is made up at your working concentration and compared against the current PWG or SEP grade on the same raw water, at stepped doses, with your clarity and settling targets as the pass mark.

What to Send for a Quotation

The full grade, quantity and destination are enough to start. These details sharpen the plan:

InputWhy it matters
Full grade with suffix, or a bag-label photoFixes base grade and ion type
Documents required by your authority or clientChecked before the quotation is finalised
Water-treatment duty, current dose and targetBaseline and pass mark for the jar test
Expected volume and destinationPricing, packaging and lead time in the quotation

Documents and Delivery

The applicable TDS is confirmed together with the selected ChinaPAM grade, and a batch COA is tied to the confirmed shipment. Any further documents your drinking-water authority or client specifies are treated as a separate confirmation, not as something the PWG or SEP suffix already answers. Packaging and lead time are confirmed in the quotation for your volume and destination.

Dosage Guide

Use the current PWG or SEP grade dose as the reference. Prepare the ChinaPAM screening grade at your working concentration, allow full hydration, and compare stepped doses on the same raw water.

Verified manufacturing credentials (ISO 9001 / 14001 / 45001, HSE)

Frequently Asked Questions — FLOPAM AN PWG and SEP Grades — Polyacrylamide Selection Route with Document Check

Is a ChinaPAM grade approved for drinking water because it replaces a PWG or SEP grade?

No. The PWG or SEP suffix is SNF’s label and proves nothing about a ChinaPAM grade. Tell us which market and project documents your drinking-water duty requires, and we confirm what can be provided before the quotation is finalised.

What do PWG and SEP mean?

The 2007 catalogue does not define them, and we do not guess. Each PWG and SEP pair carries identical published values for its base grade, so the base grade is what drives selection.

Can I pick any grade from the drinking water table?

No. The table puts two non-ionic columns (FA 920 PWG and SEP) next to fourteen anionic columns running from very low charge (AH 912, AN 905) to high charge (AN 956). Choosing by the shared heading alone can put the wrong ion type or charge into your process.

Which ChinaPAM lane starts for FA 920 or AH 912 PWG/SEP?

They are different lanes. FA 920 PWG and SEP are listed non-ionic, so the screening start is our nonionic powder grade 1003. AH 912 PWG and SEP are listed very low charge — anionic, not non-ionic — so the start is our very-low-charge anionic grade 1082, the same lane our FLOPAM AH 912 SH page already uses. A jar test on your water selects the final grade.

Which documents come with the supply?

The TDS for the selected ChinaPAM grade and a batch COA tied to the confirmed shipment. Any additional drinking-water documents your authority requires are confirmed case by case before quotation is finalised.

Trademark notice. SNF FLOPAM AN PWG and SEP grades and all other third-party product and brand names on this page are trademarks or registered trademarks of their respective owners. Henan Jinghua New Material Technology Co., Ltd. is not affiliated with, endorsed by, sponsored by or authorised by those owners, and no such relationship is implied. Those names are used here for the sole purpose of identifying the products our grades are compared against, which is necessary to describe what we supply. Our products are separately branded ChinaPAM grades and are not licensed copies. Grade descriptors quoted for third-party products are taken from each manufacturer’s own published literature and follow that manufacturer’s own scale; we do not publish figures those manufacturers do not publish. Performance on your process should be confirmed by jar test or CST test before any change of supply.

Quick Quote